Model : CV500-CN432.
Cable I / O connection.
40M cable length.Model: C1000H-TER01.
Each node requires one of the ends of the network.Model: C500-CN222N.
Cable length 2m.
CV Series C Series Expansion ← → I / O device CPU Connecting cable(Vertical-wired)Unit type: CJ1 CPU Bus Units.
Product Name: Serial Communications nits CJ2H-CPU68-EIP REFERENCE MANUAL.
Specifications:Communications Interface,
1 RS-232C port and 1 RS-422A/485 port;
Communications functions,
The following functions can be,
selected for each port:
Protocol macro Host Link,
NT Links (1:N mode)Serial Gateway,
No-protocol Modbus-RTU Slave
CJ2H-CPU68-EIP
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.38A; 24V,--.
Standards: UC1, N, L, CE.
The Serial Communications Units That Enable,
High-speed Connections with External Devices CJ2H-CPU68-EIP REFERENCE MANUAL.
Each Serial Communications Unit provides two,
serial communications ports: RS-232C and,
RS-422A/485, and the serial communications,
mode can be set separately for each port from,
Protocol Macro, Host Link, NT Link,
Serial Gateway, and No-protocol. Model: CPM2C-PA201. Input: 100 to 240 V AC.Output: 24 V DC/600 mA CJ2H-CPU68-EIP REFERENCE MANUAL. Number of outputs: 16 pts.
Max. switch-ing capacity: 50 mA at 4.5 V DC to 300 mA at 26.4 V.
External connector: Terminal block.
Weight: 180 g max.Model : CV2000-CPU01-V1.
SFC / Ladder 2, 048 (with RAM62K words, the top internal link).Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Analog Output Unit.
Output points : 4 inputs.
Signal range selection:
Set separately for each input.
Signal range: 0 to 10 V, ±10 V,
0 to 5 V, ±5 V, 0 to 1 V, ±1 V.
Conversion speed (resolution):
40ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.12A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previouss systems CJ2H-CPU68-EIP Communications Commands Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CJ2H-CPU68-EIP Communications Commands Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.