C500-IA I/O Unit AC Input 32 pts C500-IA223(3G2A5-IA223).
AC200-240V 10mA.For 10-slot Backplane.C500-RT SYSMAC BUS Remote I/O Master Slave Wired C500-RT201.
Master station unit remote I/O.Unit type: CJ1 Basic I/O Units.
Product name: Transistor Output Units.
Specifications: Output type, Sourcing;
I/O points, 32 outputs;
Maximum switching capacity, 24VDC,
0 CP1W-8ED I/O Wiring Diagram. 5A Short-circuit protection;
Commons, 16 points, 1 common;
External connection, MIL connector
CP1W-8ED
No. of words allocated: 2 words.
Current consumption: 5V, 0.15A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices CP1W-8ED I/O Wiring Diagram.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput. Model: C200H-OA224.
No. of points: 12 pts.
Specifications: 0.5 A, 250VAC.Model: C200HW-PA204R.
Supply voltage: 100 to 120 VAC, 200 to 240 VAC.
Comments: With output contacts during operation.C1000H-SL SYSMAC BUS SYSMAC LINK C1000H-SLK21-V1 CP1W-8ED I/O Wiring Diagram. Name: Three-tier Screw Terminal Block.
Specifications: Inputs; 16 inputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. C500-AD/3G2A5-AD Special I/O Unit Analog Input C500-AD007(3G2A5-AD007).
Input: 4 pts.
Specification: 0~+10V.Unit type: CS1 Basic I/O Units.
Product name: B7A Interface Unit.
Specifications: 32 inputs/outputs.
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HGG/HE Expansion I/O Rack, No CP1W-8ED Manual.
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No.
Words required: 2 input words and 2 output words.
Current consumption: 5V systeem, 0 CP1W-8ED Manual. 09A;
26 V system, --.
Standards: UC1, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control.