Short protection for 10-pin terminal block (package of 10 covers). 12 pts.Unit classification: CJ1 Special I/O Units.
Product name: Highspeed Counter Unit.
Specifications; Countable channels: 2 ,
Encoder A and B inputs, pulse input Z signals;
Open collector Input voltage: 5VDC, 12V, or 24V,
(5V and 12V are each for one axis only CRT1-ID16SY-1 UL Standards and CSA Standards. ) ,
Max. counting rate, 50kHz
CRT1-ID16SY-1
No. of unit numbers allocated: 4.
Current consumption: 5V, 0.28A; 24V, --.
Standards: UC1, N, L, CE.
High-Speed, Flexible Control With A,
Wide Array of Features.
Equipped with 2 Counters and counts ,
over a maximum binary range of 32-bits.
Accepting input pulse frequencies of up,
to 500 kHz allows precise control of fast motions CRT1-ID16SY-1 UL Standards and CSA Standards.
The Unit is equipped with 2 Digital Inputs,
2 Digital Outputs and 30 Soft Outputs.
A maximum response time of 0.5 ms guarantees,
high-speed closed loop control of applications. I/O points: 256 pts.
Program capacity(words): 7.2 K.
DM capacity (words): 6 K.
RS-232C port: YES.
Pulse I/O: YES.C500-RT SYSMAC BUS Remote I/O Master Slave Wired C500-RT001-PV1.
APF/PCF, With the optical connector 1 CRT1-ID16SY-1 UL Standards and CSA Standards. Name: e-CON Connectors.
Specifications: Inputs; 16 inputs; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Output method: Analog resolution: 1/6000.
Analog Inputs: 4.Power supply: DC power supply.
Output method: Transistor output source type.
Inputs points: 12 points.
Outputs points: 8 points.Unit name: Loop Control Boards.
Specifications: No. of function blocks:
500 blocks max.
Standards: UC1, N, CE.
The open nature of the PLCs is joined,
by integrating harddware, software,
and networking to meet your needs CRT1-ID16SY-1 Manual.
Increasing amounts of information,
standardization, and open standards,
form the basis for achieving hardware,
and networking capabilities for process control.
A wide raange of software that can be easily,
used by design, development, and maintenance,
personnel makes operating and maintaining,
the system far easier CRT1-ID16SY-1 Manual.