C500-IM I/O Unit INPUT MODULE 32POINT 24VAC/DC C500-IM212(3G2A5-IM212).
AC/DC12-24V 10mA。Model : CV2000-CPU01-V1.
SFC / Ladder 2, 048 (with RAM62K words, the top internal link).Number of outputs: 32 pts.
Max. switch-ing capacity: 16 mA at 4.5 V DC to 100 mA at 26.4 V.
External connector: Connector CRT1-OD16SL UL Standards and CSA Standards.
Weight: 180 g max.I/O bits: 5, 120 (Expan-sion Racks: 7)
CRT1-OD16SL
Program capacity: 30K steps.
Data memory capacity: 64K words (DM: 32K words, EM: 32K words ×1 banks).Cover for 10-pin terminal block.
Terminal cover for 8-point or 5-point I/O Units.Model: C500-CN422.
C500-CN Cable Position Control Unit Connecting Cable: To connect C500-TU002-E 4m C500-CN422.C200H Accessory Programming Console Adapter C200H-BP001 CRT1-OD16SL UL Standards and CSA Standards. Model: C500-AE001(3G2A5-AE001).
Output line driver converts the input open-collector output incremental encoder form, taking the position control unit.Name: Heat/Cool Temperature Control Module.
Model: C200H-TV003.
Sensor: Thermocouple: R, S, K, J, T, E, B, N, L, U.
Control output: Current output(transistor output used for cooling outputs).Unit type: CS1 Basic I/O Units.
Product name: B7A Interface Unit CRT1-OD16SL UL Standards and CSA Standards.
Specifications: 16 inputs/outputs.
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HG/HE Expansion I/O Rack, No.
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No.
Words required: 1 input word and 1 output word.
Current consumption: 5V system, 0.09A;
26 V system, --.
Standards: UC1, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Resistance Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100.
Conversion speed (resolution):
100 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.15A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spacce compared,
with previous systems CRT1-OD16SL Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CRT1-OD16SL Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.