Unit type: CJ1 Basic I/O Units.
Product name: DC Input/Transistor Output Units.
Specifications: Output type, Sinking;
I/O points, 32 inputs, 32 outputs;
Input voltage,Input current, 24VDC, 4.1mA,
12 to 24VDC, 0.3A;
Commons, 16 points, 1 common;
External connection, MIL connector.
No. of words allocated: 4 words CS1W-DA08C Instruction Manual.
Current consumption: 5V, 0.14A; 24V, --
CS1W-DA08C
Standards: UC1, N, CE.
A Wide Range of Basic Mixed,
I/O Units for Different Applications,
and Wiring Methods.
One Mixed I/O Unit has connectors for,
both inputs and outputs.
Use Mixed I/O Units to easily ,
build space-saving systems.
Power supply: AC power supply.
Output method: Relay output.
Inputs points: 12 points CS1W-DA08C Instruction Manual.
Outputs points: 8 points.Number of inputs: 8 pts.
Input Voltage: 12 to 24V DC.
Input Current: 10 mA.Power supply: DC power supply.
Output method: Relay output.
Inputs points: 6 points.
Outputs points: 4 points.2 thermocouple inputsUM: 31.2K words.
DM: 6K words.
EM: 6Kx3 banks(18K) words.
Instruction processing time (basic instructions): 0.1 µ.s min.
No. of I/O points: 1, 184 points.
Max CS1W-DA08C Instruction Manual. no.of con-necting Expansion I/O Racks: 3 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.Power supply: DC power supply.
Output method: Relay output.
Inputs points: 24 points.
Outputs points: 16 points.C500-OD I/O Unit Transistor Output 64 pts C500-OD213(3G2A5-OD213).
DC24V 0.1A.I/O Cable (for I/O to Interface Racks) 2 m (L) CV500-CN222Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 8 inputs.
Signal range: 4 to 20 mA, 0 to 10 V,
0 to 5 V, 1 to 5 V.
Conversion speed (resolution):
250ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 26V, 0.06A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spaace compared,
with previous systems CS1W-DA08C Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1W-DA08C Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.