Actuator: One-way roller arm lever (horizontal).
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 2NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC D4B-1A71N INSTRUCTION sheet.
M12-connector models are available, saving on labor and,
simplifying replacement
D4B-1A71N
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Actuator: Adjustable roller lever, form lock (metal lever, rubber roller).
Conduit size: 2-conduit; M20 D4B-1A71N INSTRUCTION sheet.
Built-in switch mechanism: 1NC/1NO(Snap-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability D4B-1A71N INSTRUCTION sheet.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Actuator: Roller plunger.
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 2NC(Snap-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Specifications: Inputs; PNP (- common);
16 points.
I/O connections: M3 screw terminals.
Rated internal circuit poweer supply voltage:
Supplied from Basic Unit D4B-1A71N Manual.
I/O power supply voltage: 24 VDC.
A Smart Slave with a 3-tier Terminal,
Block That Means Wiring Locations,
Are Easy to Understand with No,
Sharing of Terminals.
Easy wiring with nno sharing of terminals D4B-1A71N Manual.
Easy-to-understand wiring locations.
No relay terminal block terminals required.
Detachable cassette-type circuit sections.