LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON D4N-2E26 Manual D4N-2E26 INSTRUCTION sheet
Product model: D4N-2E26
Name: safety limit switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Ratings: Standard load; 5 A at 250 VAC, 4 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Sealed pin plunger.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models D4N-2E26 INSTRUCTION sheet. )
Sealing characteristics that meet IEC IP67 degree of protection D4N-2E26
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables D4N-2E26 INSTRUCTION sheet.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Release Key Type: Special (resin).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Solenoid lock Mechanical release D4N-2E26 INSTRUCTION sheet.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 6-contact Model,
Insert the built-in switch (N, P, Q or R) into the blank @.
Conduit size (See Note.): M20.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key inssertion point D4N-2E26 Manual.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lockk Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames D4N-2E26 Manual.
The plastic material makes the Slide Key suitable,
for lightweight doors.
Related products
OMRON
Safety Limit Switch
D4N-4187
OMRON Safety Limit Switch D4N-4187
Actuator: Plastic rod. Conduit size: 1-
OMRON
Pull-reset Safety Limit Switch
D4N-9A2HR
OMRON Pull-reset Safety Limit Switch D4N-9A2HR
Actuator: Adjustale roller lever, form
OMRON
Safety Limit Switch
D4N-2D32
OMRON Safety Limit Switch D4N-2D32
Actuator: Roller plunger. Conduit size:
OMRON
Safety Limit Switch
D4N-8231
OMRON Safety Limit Switch D4N-8231
Actuator: Plunger. Conduit size: 2-cond