LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON D4N-3D2G Manual D4N-3D2G INSTRUCTION sheet
Product model: D4N-3D2G
Name: safety limit switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Actuator: Roller lever (resin lever, resin roller).
Conduit size: 1-conduit; M12 connector.
Built-in switch mechanism: 1NC/1NO MBB(Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms D4N-3D2G INSTRUCTION sheet.
(Slow-action models with MBB contacts are available D4N-3D2G)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Specifications: Input, PNP (- common), 8 points D4N-3D2G INSTRUCTION sheet.
I/O connections: Sensor I/O connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: Supplied from the communications connector.
Environment-resistive (IP67) I/O.
Terminals with Troubleshooting.
Functions such as Sensor Power.
Supply Short-circuit Detection.
Equipped with the standard Smart Slave functions that provide powerful,
preventative maintenance and troubleshooting capabilities D4N-3D2G INSTRUCTION sheet.
High degree of environmental resistance with dust-proof,
and drip-proofconstruction.
Power supply wiring is not required for input devices.
Connect heavy-load devices (up to 1.5 A).
Power supply wiring is not required for input devices such as sensors.
(Power supply wiring is required for output devices.)
Detects ground faults or disconnects and notifies the Master.
Release Key Type: Standard (metal).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (without indicator).
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 4-contact Model,
Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank @.
Conduit size (See Note.): M20.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key inssertion point D4N-3D2G Manual.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lockk Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames D4N-3D2G Manual.
The plastic material makes the Slide Key suitable,
for lightweight doors.
Related products
OMRON
Safety Limit Switch
D4N-9B26
OMRON Safety Limit Switch D4N-9B26
Actuator: Roller lever resin lever, ea
OMRON
Safety Limit Switch
D4N-9122
OMRON Safety Limit Switch D4N-9122
Actuator: Roller lever metal lever, res
OMRON
Safety Limit Switch
D4N-6E2G
OMRON Safety Limit Switch D4N-6E2G
Actuator: Adjustale roller lever, form
OMRON
Safety Limit Switch
D4N-4FRE
OMRON Safety Limit Switch D4N-4FRE
Actuator: Fork lever lock right operati