Ratings: Standard load; 0.1 A at 125 VAC, 0.1 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Sealed crossroller plunger.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models D4N-4D87 INSTRUCTION sheet. )
Sealing characteristics that meet IEC IP67 degree of protection
D4N-4D87
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables D4N-4D87 INSTRUCTION sheet.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Actuator: Adjustable roller lever, form lock (metal lever, resin roller).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 1NC/1NO (Slow-action) D4N-4D87 INSTRUCTION sheet.
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Release key type: Special release key.
Indicator: Green.
Lock and release types: Solenoid lock Mechanical release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 3NC+3NC.
Conduit opening: G1/2.
Holding Force of 3,000 N.
Two safety circuits aand two monitor contacts provide an,
array of monitoring patterns D4N-4D87 Manual.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas. D4N-4D87 Manual.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection.