Product model: D4N-5D2HR
Name: pull-reset safety limit switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Ratings: Standard load; 4 A at 30 VDC.
Cable: VCTF cable *2.
Actuator: Roller plunger.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection D4N-5D2HR INSTRUCTION sheet.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material D4N-5D2HR
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers D4N-5D2HR INSTRUCTION sheet.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Head material: Plastic*1.
Release key position: Bottom.
Release key type: Standard (resin).
Solenoid voltage/indicator: Solenoid: 24 VDC, Orange LED: 10 to 115 VAC/VDC D4N-5D2HR INSTRUCTION sheet.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch and,
lockmonitor switch contacts)(slow-action) Certified direct,
opening NC contact: 2NC/1NO+2NC.
Conduit opening: M20.
Best-selling Guard Lock Safety-door.
Switch Available in Several.
Compact, Multi-contact Models.
Selectable Operation Key insertion direction and,
adjustable mounting ensure installation flexibility.
Built-in switches with multiple-contact construction are available.
Key holding force of 1,300 N minimum.
Can be used for either standard loads or microloads.
Lineup includes models with a conduit size of M20.
IP67 degree of protection.
Variety of Metallic Heads Available. Features: Usable by bending tip of antenna; Overtravel of 20 mm max.
Actuator: Coil spring.
Item: Supply voltage (Power supply); DC.
Unique 18-mm-dia. Capacitive Touch.
Switch with Choice of Three Actuators is.
Activated with Only a Very Slight.
Physical Contact.
Only a slight activation force is required, enabling detecting micro.
deflections, thin wires, or thin-plate conductors (e.g., steel or stainless).
Application possible for non-conductors by indirectly connecting to groundd D4N-5D2HR Manual.
Instantaneous operation upon contact with extremely limited,
hysteresis for high-precision position detection.
Diameter of only 18 mm with standard built-in amplifier, operation,
indicator, and sensitivity adjustment.
Confoorms to IEC IP67 D4N-5D2HR Manual.
Freely replaceable antenna with screw mounting.
Free attachment to enable changing the antenna shape according to the application.
Related products
OMRON
Safety Limit Switch
D4N-8120
OMRON Safety Limit Switch D4N-8120
Actuator: Roller lever resin lever, res
OMRON
Safety Limit Switch
D4N-4131
OMRON Safety Limit Switch D4N-4131
Actuator: Plunger. Conduit size: 1-cond
OMRON
Safety Limit Switch
D4N-1D26
OMRON Safety Limit Switch D4N-1D26
Actuator: Roller lever metal lever, ea
OMRON
Pull-reset Safety Limit Switch
D4N-4D2GR
OMRON Pull-reset Safety Limit Switch D4N-4D2GR
Actuator: Adjustale roller lever, form