OMRON D4N-7B2HR Manual D4N-7B2HR INSTRUCTION sheet
Product model: D4N-7B2HR
Name: pull-reset safety limit switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Short/disconnection detection: Supported.
Specifications: Outputs, NPN (- common), 32 points.
I/O connections: Clamp terminals.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
Reduced Wiring and Labor on Factory Sites with Screw-less Terminal Wiring D4N-7B2HR INSTRUCTION sheet.
Screw-less structure eliminates tightening work D4N-7B2HR
Detachable terminal blocks for easier maintenance.
Single-step wiring by simply inserting pole terminals. Release Key Type: Standard (metal).
Wiring method: Connector.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 6-contact Model,
Insert the built-in switch (N, P, Q or R) into the blank @ D4N-7B2HR INSTRUCTION sheet.
Conduit size (See Note.): 1/2-14NPT.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices D4N-7B2HR INSTRUCTION sheet.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames.
The plastic material makes the Slide Key suitable,
for lightweight doors. Ratings: Standard load; 0.1 A at 125 VAC, 0.1 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Plastic rod.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cabble lengths of 3 and 5 m available on standard models D4N-7B2HR Manual.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
connfirmation of operation D4N-7B2HR Manual.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)
Related products
OMRON
Pull-reset Safety Limit Switch
D4N-8B20R
OMRON Pull-reset Safety Limit Switch D4N-8B20R
Actuator: Roller lever resin lever, res
OMRON
Pull-reset Safety Limit Switch
D4N-1B2HR
OMRON Pull-reset Safety Limit Switch D4N-1B2HR
Actuator: Adjustale roller lever, form
OMRON
Safety Limit Switch
D4N-6262
OMRON Safety Limit Switch D4N-6262
Actuator: One-way roller arm lever hori
OMRON
Safety Limit Switch
D4N-2C31
OMRON Safety Limit Switch D4N-2C31
Actuator: Plunger. Conduit size: 1-cond