OMRON D4N-8D2G Manual D4N-8D2G INSTRUCTION sheet
Product model: D4N-8D2G
Name: safety limit switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Actuator type: Coil spring.
Compact Vertical Models Sized for Asian.
Standards.
Compact new design approximately 1/3 the size of OMRON,
vertical Limit Switches.
Structure enables the terminal section to be fully opened for,
easy wiring.
RoHS complaint.
Degree of protection: IP65. Ratings: 1 A at 125 VAC D4N-8D2G INSTRUCTION sheet.
LED indicator: With indicator.
Actuator: Sealed pin plunger D4N-8D2G
Many Models Including Roller Lever.
Switches are Only 16-mm Thick with Connector.
New center roller lever models that enable ganged mounting.
of up to 6 Switches.
Cable connectors for easy Switch replacement.
Triple-seal construction to provide IEC IP67 degree of protection.
Operation indicators available for easy monitoring,
(standard indicator is lit when Switch is not operating) D4N-8D2G INSTRUCTION sheet.
Approved by UL and CSA.
(Ask your OMRON representative for Information on approved models.) Release Key Type: Standard (metal).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (without indicator).
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 4-contact Model,
Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank @ D4N-8D2G INSTRUCTION sheet.
Conduit size (See Note.): G1/2.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key inssertion point D4N-8D2G Manual.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lockk Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames D4N-8D2G Manual.
The plastic material makes the Slide Key suitable,
for lightweight doors.
Related products
OMRON
Safety Limit Switch
D4N-4272
OMRON Safety Limit Switch D4N-4272
Actuator: One-way roller arm lever vert
OMRON
Safety Limit Switch
D4N-2125
OMRON Safety Limit Switch D4N-2125
Actuator: Roller lever resin lever, met
OMRON
Safety Limit Switch
D4N-4287
OMRON Safety Limit Switch D4N-4287
Actuator: Plastic rod. Conduit size: 1-
OMRON
Safety Limit Switch
D4N-622G
OMRON Safety Limit Switch D4N-622G
Actuator: Adjustale roller lever, form