LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON D4NH-1CAS Manual D4NH-1CAS INSTRUCTION sheet
Product model: D4NH-1CAS
Name: safety-door hinge switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Ratings: Standard load; 5 A at 250 VAC, 4 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Pin plunger.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models D4NH-1CAS INSTRUCTION sheet. )
Sealing characteristics that meet IEC IP67 degree of protection D4NH-1CAS
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables D4NH-1CAS INSTRUCTION sheet.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Receptacle box: G 1/2 Conduit.
Indicator: Without indicator.
Actuator: Flexible rod, Coil spring.
Approved standards: UL, CSA D4NH-1CAS INSTRUCTION sheet.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13).
Wide standard operating temperature range:
-40°C to +100°C (standard type).
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models available for complex operations.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model.) Actuator: Pin plunger.
Type: M8.
Operation Indicator: None.
Repeat accuracy: 1 µm max.
Operating force OF max: 0.49 N.
Cable lead outlet: Lead outlet, Pre-wired; Length, 1 m.
Degree of protection: IP67.
High-precision Switch for Detecting Micron-unit,
Displacementt D4NH-1CAS Manual.
Ideal for detecting and measuring wear of cutting,
tools or for original point of work.
Ceramic plungers on M5, M8, and slim models for,
superior abrasion resistance and resistance to,
temperature changes.
Direct input posssible to microprocessors and,
programmable controllers D4NH-1CAS Manual.
A version with screw-type cable connector available,
for easy installation and maintenance.
Related products
OMRON
Safety-door Hinge Switch
D4NH-2EBC
OMRON Safety-door Hinge Switch D4NH-2EBC
Actuator: Arm lever. Conduit size: 1-co
OMRON
Safety-door Hinge Switch
D4NH-2BBC
OMRON Safety-door Hinge Switch D4NH-2BBC
Actuator: Arm lever. Conduit size: 1-co
OMRON
Safety-door Hinge Switch
D4NH-4DAS
OMRON Safety-door Hinge Switch D4NH-4DAS
Actuator: Shaft. Conduit size: 1-condui
OMRON
Safety-door Hinge Switch
D4NH-1FBC
OMRON Safety-door Hinge Switch D4NH-1FBC
Actuator: Arm lever. Conduit size: 1-co