Release key type: Trapped key *1.
Indicator: Green.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 2NC/1NO+3NC.
Conduit opening: M20.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns D4NL-RK INSTRUCTION sheet.
Standard gold-clad contacts enable use with ordinary loads,
and microloads
D4NL-RK
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection. Contact type: Silver plated D4NL-RK INSTRUCTION sheet.
Terminal specification: right angle terminal.
Straight terminal: needle shaped button type.
Super small (6.5 x 8.2 x width depth of high quality 2.7mm) only 0.3g speed switch
Although it is super small, but with fast moving structure, good electrical characteristics.
Contact with gold plated contacts for silver plated contacts and small loads.
Can be used in small audio equipment, optical equipment, communication equipment, etc D4NL-RK INSTRUCTION sheet. .
A place of high demand and high reliability. Ratings: Standard load; 0.1 A at 125 VAC, 0.1 A at 30 VDC.
Cable: VCTF cable *2.
Actuator: Roller lever, high sensitivity.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
CCable lengths of 3 and 5 m available on standard models D4NL-RK Manual.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
connfirmation of operation D4NL-RK Manual.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)