LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON D4SL-N2GFA-D Manual D4SL-N2GFA-D INSTRUCTION sheet
Product model: D4SL-N2GFA-D
Name: guard lock safety-door switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Ratings: Standard load; 4 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Roller lever, high sensitivity.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models D4SL-N2GFA-D INSTRUCTION sheet. )
Sealing characteristics that meet IEC IP67 degree of protection D4SL-N2GFA-D
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables D4SL-N2GFA-D INSTRUCTION sheet.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Actuator: Fork lever lock (right operation).
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 2NC (Slow-action).
Popular Safety Limit Switches D4SL-N2GFA-D INSTRUCTION sheet.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC.
Type: Welding / wire type, with right column.
Driving rod: swing lever type.
Terminal specification: welding.
Contact specificatioons: 1c D4SL-N2GFA-D Manual.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used ffor easy long stroke specifications (OT reference value: 1 D4SL-N2GFA-D Manual. 4mm).
Without harmful substances to the environment, the lead type has also been lead-free.