LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON D4SL-N2HFG-DN Manual D4SL-N2HFG-DN INSTRUCTION sheet
Product model: D4SL-N2HFG-DN
Name: guard lock safety-door switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Actuator: Fork lever lock (right operation).
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 3NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available D4SL-N2HFG-DN INSTRUCTION sheet. )
M12-connector models are also available, saving on labor and,
simplifying replacement D4SL-N2HFG-DN
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Ratings: Standard load; 5 A at 125 VAC D4SL-N2HFG-DN INSTRUCTION sheet.
Cable: VCTF oil-resistant cable *1.
Actuator: Plastic rod.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material D4SL-N2HFG-DN INSTRUCTION sheet.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Ratings: Standard load; 5 A at 125 VAC.
Cable: VCTF cable *2.
Actuator: Roller lever, high sensitivity.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable llengths of 3 and 5 m available on standard models D4SL-N2HFG-DN Manual.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
connfirmation of operation D4SL-N2HFG-DN Manual.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)