Type: Welding / wire type, with left column.
Driving rod: swing lever type.
Terminal specifications: with wire, under the lead.
Contact specifications: 1c.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment D4SL-N2PDG-D4 INSTRUCTION sheet.
No swing bars are also used for easy long stroke specifications (OT reference value: 1
D4SL-N2PDG-D44mm).
Without harmful substances to the environment, the lead type has also been lead-free. Head material: Plastic*1.
Release key position: Bottom.
Release key type: Special release key(resin).
Solenoid voltage/indicator: Solenoid: 24 VDC, Orange LED: 10 to 115 VAC/VDC D4SL-N2PDG-D4 INSTRUCTION sheet.
Lock and release types: Solenoid lock Mechanical release.
Contact configuration(door open/closed detection switch and,
lockmonitor switch contacts)(slow-action) Certified direct,
opening NC contact: 3NC+2NC.
Conduit opening: Pg13.5.
Best-selling Guard Lock Safety-door.
Switch Available in Several.
Compact, Multi-contact Models.
Selectable Operation Key insertion direction and,
adjustable mounting ensure installation flexibility D4SL-N2PDG-D4 INSTRUCTION sheet.
Built-in switches with multiple-contact construction are available.
Key holding force of 1,300 N minimum.
Can be used for either standard loads or microloads.
Lineup includes models with a conduit size of M20.
IP67 degree of protection.
Variety of Metallic Heads Available. Receptacle box: G 1/2 Conduit.
Indicator: With neon lamp indicator (AC).
Actuator: Roller lever *1, Maintained *2.
Approved standards: UL, CSA.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13).
Wide standard ooperating temperature range:
-40°C to +100°C (standard type) D4SL-N2PDG-D4 Manual.
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models aavailable for complex operations D4SL-N2PDG-D4 Manual.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model.)