Actuator: Plunger.
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 1NC/1NO(Snap-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available D4SL-N2QFA-D4 INSTRUCTION sheet. )
M12-connector models are also available, saving on labor and,
simplifying replacement
D4SL-N2QFA-D4
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC D4SL-N2QFA-D4 INSTRUCTION sheet.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC D4SL-N2QFA-D4 INSTRUCTION sheet. Actuator: Shaft.
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 1NC/1NO (Slow-action).
Compact, Plastic-body Safety-door.
Hinge Switch Designed for Saving.
Space in Machines and Other.
Equipment.
Lineup includes three contact models with 2NC/1NO and.
3NC contact forms in addition to the previous contact forms.
1NC/1NO, and 2NC. Models with MBB contacts are also available.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads. Actuator: Plunger.
Conduit openings: G1/2 (PF1/2).
1NC/1NO (Snap-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever.
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion D4SL-N2QFA-D4 Manual.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NNEMA 3, 4, 4X, 6P, and 13) D4SL-N2QFA-D4 Manual.
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.