LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON D4SL-N3NDA-DN Manual D4SL-N3NDA-DN INSTRUCTION sheet
Product model: D4SL-N3NDA-DN
Name: guard lock safety-door switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Ratings: Standard load; 5 A at 125 VAC.
Cable: VCTF oil-resistant cable *1.
Actuator: Crossroller plunger.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models D4SL-N3NDA-DN INSTRUCTION sheet. )
Sealing characteristics that meet IEC IP67 degree of protection D4SL-N3NDA-DN
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers D4SL-N3NDA-DN INSTRUCTION sheet.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Type: Welding / wire type, M3 screw mounting.
Drive rod: rod type Shibai leaf.
Terminal specifications: with wire, the right side of the lead D4SL-N3NDA-DN INSTRUCTION sheet.
Contact specifications: 1a.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used for easy long stroke specifications (OT reference value: 1.4mm).
Without harmful substances to the environment, the lead type has also been lead-free. Release Key Type: Standard (metal).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (without indicator).
Lock and release type: Mechanical lock Solenoid release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 4-contact Model,
Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank @.
Conduit size (See Note.): M20.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertioon point D4SL-N3NDA-DN Manual.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lockk Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames D4SL-N3NDA-DN Manual.
The plastic material makes the Slide Key suitable,
for lightweight doors.