LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON D4SL-N4EFA-D Manual D4SL-N4EFA-D INSTRUCTION sheet
Product model: D4SL-N4EFA-D
Name: guard lock safety-door switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Actuator: Adjustable rod lever.
Conduit openings: G1/2 (PF1/2).
1NC/1NO (Snap-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts D4SL-N4EFA-D INSTRUCTION sheet.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever D4SL-N4EFA-D
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NEMA 3, 4, 4X, 6P, and 13) D4SL-N4EFA-D INSTRUCTION sheet.
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.
Actuator type: Wire spring.
Compact Vertical Models Sized for Asian.
Standards.
Compact new design approximately 1/3 the size of OMRON,
vertical Limit Switches.
Structure enables the terminal section to be fully opened for,
easy wiring D4SL-N4EFA-D INSTRUCTION sheet.
RoHS complaint.
Degree of protection: IP65. Release Key Type: Special (resin).
Wiring method: Connector.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Mechanical lock Solenoid release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 6-contact Model,
Insert the built-in switch (N, P, Q or R) into the blank @.
Conduit size (See Note.): 1/2-14NPT.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertiion point D4SL-N4EFA-D Manual.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lockk Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames D4SL-N4EFA-D Manual.
The plastic material makes the Slide Key suitable,
for lightweight doors.