OMRON D4SL-N4VFG Manual D4SL-N4VFG INSTRUCTION sheet
Product model: D4SL-N4VFG
Name: guard lock safety-door switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
The drive rod: rod type Shibai leaf.
Contact specifications: 1b.
Rating: small load with 0.1A.
For the automobile, industrial vehicles, mechanical testing of the anti immersion type (in line with IP67)
Use M4 screw to achieve a little installation.
Using a strong fixed leaf swing rod which can adapt to the harsh environment D4SL-N4VFG INSTRUCTION sheet.
Full consideration of environmental protection, the installation of the wire also lead to lead free D4SL-N4VFG Actuator: One-way roller arm lever (horizontal).
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 3NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC D4SL-N4VFG INSTRUCTION sheet.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Type: Welding / wire type, with right column.
Drive rod: needle shaped button type D4SL-N4VFG INSTRUCTION sheet.
Terminal specifications: with wire, the left side.
Contact specifications: 1b.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used for easy long stroke specifications (OT reference value: 1.4mm).
Without harmful substances to the environment, the lead type has also been lead-free. Receptacle box: G 1/2 Conduit.
Indicator: Without indicator.
Actuator: Top plunger, Adjustable.
Approved standards: UL, CSA.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13).
Wide standarrd operating temperature range:
-40°C to +100°C (standard type) D4SL-N4VFG Manual.
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models aavailable for complex operations D4SL-N4VFG Manual.
Approved by UL, CSA, and CCC (Chinese standard).