Product model: E2E-X5MY1-M1
Name: proximity switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Size: M8(Stainless steel)(See note 2.); Double; Unshielded.
Sensing distance: 4 mm.
Connecting method (See note 1.): Pre-wired.
Body length: Short.
Output configuration: PNP.
Operation mode NO.
A new generation in global applications. Output mode: E3C-LS3R detection mode: qualified reflection type E2E-X5MY1-M1 INSTRUCTION sheet.
Detection distance: 30 positive and negative 3mm.
Purpose: small,
Small thin space probe;
Interference prevention function with close installationSensing method: Through-beam type E2E-X5MY1-M1
Sensing distance: 300 mm.
Output type: NPN output.
Output configuration: Light-ON.
Cable length: 2 m.
Cable length from emitter to amplifier: 0.5 m.
Compact, Thin-profile.
Photomicrosensor with special amplifier E2E-X5MY1-M1 INSTRUCTION sheet.
Slim amplifier (50 × 7.5 × 12 mm) can be handled like a cable.
Provided with two operation indicators, enabling monitoring from the,
amplifier housing and sensor head.
Simple wiring with a 3-conductor cable.
Wide operating voltage range: 12 to 24 VDC. Size: M8(Stainless steel)(See note 2.); Single; Unshielded.
Sensing distance: 2 mm.
Connecting method (See note 1.): Pre-wired.
Body length: Short E2E-X5MY1-M1 INSTRUCTION sheet.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications. The main body: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver)
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
FFurther performance improvement E2E-X5MY1-M1 Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E2E-X5MY1-M1 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Related products
OMRON
Standard Proximity Sensor
E2E-X5Y1-M1-Z
OMRON Standard Proximity Sensor E2E-X5Y1-M1-Z
Appearance: M18. Sensing distance: 5 mm
OMRON
Standard Proximity Sensor
E2E-X5F1-Z 2M
OMRON Standard Proximity Sensor E2E-X5F1-Z 2M
Appearance: M18. Sensing distance: 5 mm
OMRON
Standard Proximity Sensor
E2E-X5Y2-M1-Z
OMRON Standard Proximity Sensor E2E-X5Y2-M1-Z
Appearance: M18. Sensing distance: 5 mm
OMRON
Standard Proximity Sensor
E2E-X5MY2-M1-Z
OMRON Standard Proximity Sensor E2E-X5MY2-M1-Z
Appearance: M12. Sensing distance: 5 mm