High performance price ratio standard type proximity sensor.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC two-wire / connector type.
Polarity: none.
Shape: shield, M12.
Detection range: 3mm.
Action mode: NO. Reliable Detection Unaffected by PCB.
Holes or Notches E3S-AT71-D INSTRUCTION sheet.
High-limit E3S-LS3@ is suitable for incorporation in devices
E3S-AT71-D
Wide-range E3S-LS3@W is ideal for detecting tall components,
mounted on boards.
Timer function models available. Size: Shielded, M12.
Sensing distance: 2 mm.
Output: DC 2-Wire (polarity).
Operation mode: NO.
Highly Durable Proximity Sensor for.
Tough Environments.
Completely stainless-steel housing.
Aluminum chip immunity E3S-AT71-D INSTRUCTION sheet.
Embedding installation to metal (steel) fittings.
Chemical resistance certified by Ecolab Europe.
Lineup includes pre-wire models and DC 3-wire NPN output,
models with fluororesin coating. E3F3-D67 detection method: diffuse reflection type,
Lead extraction: CN M12,
Type: Plastic appearance; NPN output,
Threaded cylindrical photoelectric sensor, built-in amplifier,
Photoelectric sensor with proximity sensor appearance
High anti interference with optoelectronic -IC technologyE3F3-R17M detection methods: Regression reflection type,
Lead extraction: CN M12,
Type: metal appearance; NPN output,
Threaded cylindrical photoelectric sensor, built-in amplifier,
Photoelectric sensor with proximity sensor appearance
High anti interference with optoelectronic -IC technologyOntology: terminal type, analog input type E3S-AT71-D INSTRUCTION sheet.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,,
Further performance improvement E3S-AT71-D Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E3S-AT71-D Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.