LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON E3T-FL21-M1TJ Manual E3T-FL21-M1TJ INSTRUCTION sheet
Product model: E3T-FL21-M1TJ
Name: photoelectric sensors
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function E3T-FL21-M1TJ INSTRUCTION sheet.
Event entry point: 4.
Transfer output: transfer output (special terminal) E3T-FL21-M1TJ
Remote SP:4 to 20mA input.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C E3T-FL21-M1TJ INSTRUCTION sheet.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E3T-FL21-M1TJ INSTRUCTION sheet.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Size: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase heater detection function.
Event entry point: 2.
Transfer output: -.
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of thhe thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV E3T-FL21-M1TJ Manual.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm flexible contact output E3T-FL21-M1TJ Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
Related products