LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON E3T-SL23M Manual E3T-SL23M INSTRUCTION sheet
Product model: E3T-SL23M
Name: photoelectric sensors
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 1 dia.
Protective tubing length L: 20 cm.
Lead wire type: Heat resistive.
Lead wire length M: 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E3T-SL23M INSTRUCTION sheet.
Ideal for the thermal input devices of Temperature Controllers E3T-SL23M
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 48 x 48mm.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver) E3T-SL23M INSTRUCTION sheet.
Auxiliary output: 2 independent points.
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: 2 points.
Remote SP input: there.
Transfer output: -.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points E3T-SL23M INSTRUCTION sheet.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variety of applications.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermo (sold separately).
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication. Name: Basic Unit (temperature control) *1.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 4.
Control outputs 1 and 2: Voltage output: 2 points (for SSR drive) *2.
Control outputs 3 and 4: Voltage output: 2 points (for SSR drive) *2.
Auxiliary output: None.
Functions: burnout Heater alarm, None; Event inputs, None .
Communications functions: G3ZA connection port: RS-485,
From End Unit: Port A or port B: RS-485.
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel.
Terminal: M3 terminal.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directly to thhe G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise E3T-SL23M Manual.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calcullate the PID constants with the step,
response method E3T-SL23M Manual.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit.
Related products
OMRON
Photoelectric Sensors
E3T-FT21
OMRON Photoelectric Sensors E3T-FT21
Sensing method: Through-eam Emitter
OMRON
Photoelectric Sensors
E3T-ST24
OMRON Photoelectric Sensors E3T-ST24
Sensing method: Through-eam. Connectio
OMRON
Photoelectric Sensors
E3T-ST11
OMRON Photoelectric Sensors E3T-ST11
Sensing method: Through-eam. Connectio