OMRON E3X-NA11-3 Manual E3X-NA11-3 INSTRUCTION sheet
Product model: E3X-NA11-3
Name: photoelectric sensors
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Size: 96 × 96 mm.
Control type: Position-proportional control(1 loop).
Control mode: Single-loop position-proportional control(See note.).
Outputs(control/transfer): Relay output(1 open, 1 close).
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, 4; Serial communications, No.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity E3X-NA11-3 INSTRUCTION sheet E3X-NA11-3
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller E3X-NA11-3 INSTRUCTION sheet.
When using models with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4.0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation).
DeviceNet Communications.
Data setting and monitoring can be performed without special programming E3X-NA11-3 INSTRUCTION sheet. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, E5GN-Q03TC-FLK;
Resistance thermometer input, E5GN-Q03P-FLK.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of thhe Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E3X-NA11-3 Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E3X-NA11-3 Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
Related products
OMRON
Simple Fiber Amplifier Unit
E3X-NA11 2M
OMRON Simple Fiber Amplifier Unit E3X-NA11 2M
Item: Standard models. Connection metho
OMRON
Simple Fiber Amplifier Unit
E3X-NA14V
OMRON Simple Fiber Amplifier Unit E3X-NA14V
Item: Water-resistant models. Connectio
OMRON
Simple Fiber Amplifier Unit
E3X-NA8
OMRON Simple Fiber Amplifier Unit E3X-NA8
Item: Standard models. Connection metho
OMRON
Simple Fiber Amplifier Unit
E3X-NA11F 2M
OMRON Simple Fiber Amplifier Unit E3X-NA11F 2M
Item: High-speed detection models. Conn