OMRON E3X-SD6 Manual E3X-SD6 INSTRUCTION sheet
Product model: E3X-SD6
Name: photoelectric sensors
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Control output: voltage output (SSR driver).
Auxiliary output: 2 points.
Heating wire break, SSR fault detection function: -.
Event input: -.
Communication: RS-485.
Terminal shape: screw terminal table type (main unit + terminal unit).
Power supply voltage: AC/DC24V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type E3X-SD6 INSTRUCTION sheet E3X-SD6
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating E3X-SD6 INSTRUCTION sheet.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately).
With auxiliary output (maximum 2 points), event input (maximum 1 points), the basic function is complete.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8 E3X-SD6 INSTRUCTION sheet. 5mm). Sensing method: Retro-reflective Sensors.
Appearance: Horizontal.
Connection method: Pre-wired.
Sensing distance: 7 m.
Functions: Timer Self Diagnosis Turbo External Diagnosis.
Model: PNP output.
Ordering Information.
Built-in Amplifier Photoelectric Sensors. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automaticc / manual, RUN/STOP, alarm), interactive display PV/SV E3X-SD6 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E3X-SD6 Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
Related products
OMRON
Sensor communication unit
E3X-SRT21/E3X-CIF11
OMRON Sensor communication unit E3X-SRT21/E3X-CIF11
To achieve the provincial distriution C
OMRON
Digital Fiber Amplifier Unit
E3X-DA41TW-S
OMRON Digital Fiber Amplifier Unit E3X-DA41TW-S
Item: Advanced models Twin-output model
OMRON
Digital Sensor Communication Unit
E3X-DRT21-S VER.3
OMRON Digital Sensor Communication Unit E3X-DRT21-S VER.3
Type: Device Net. The DeviceNet Communi
OMRON
Digital optical fiber sensor
E3X-ZD11 2M
OMRON Digital optical fiber sensor E3X-ZD11 2M
Super fine tuning utton. Large size of