LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON E5AN-Q3HT-N Manual E5AN-Q3HT-N INSTRUCTION Manual
Product model: E5AN-Q3HT-N
Name: digital controller
Brand: OMRON
Sort: INSTRUCTION Manual
File language: English
Distance-settable Sensor Unaffected,
by Workpiece Color and Background.
Distance-settable triangulation model unaffected by color.
Simple positioning settings using a clear LED spot.
(E3Z-LS@3/LS@8).
Detect minute steps. Size: 1/4 DIN 96 × 96 × 78 (W × H × D).
Power supply voltage: 24 VAC/VDC.
Input type: Analog (current/voltage) E5AN-Q3HT-N INSTRUCTION Manual.
Alarm output: 3.
Control output: Relay output E5AN-Q3HT-N
Functions: Heater burnout, Yes (CT1); Mounting option units, Yes.
Previous model: None.
These Best-selling General,
purpose Temperature Controllers,
Are Now Even Better.
Controllers now available with analog inputs.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm) E5AN-Q3HT-N INSTRUCTION Manual.
Manual output provided.
Easy setting with 11-segment displays.
New protocol called Modbus is installed in the,
models with communications.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33. Appearance: L-shaped.
Sensing method: Through-beam type (with slot).
Cable length: 2 m.
Sensing distance: 5 mm (slot width) E5AN-Q3HT-N INSTRUCTION Manual.
configuration Output: Light-ON.
Indicator mode: Incident light.
Model: NPN output.
Slim, Compact Photomicrosensor.
that is still easy to use.
Compact, thin profile enables dense mounting.
Indicator is visible from both sides.
Wide operating voltage range: 5 to 24 VDC. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 1 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / mmanual, RUN/STOP, alarm), interactive display PV/SV E5AN-Q3HT-N Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5AN-Q3HT-N Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
Related products