LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON E5AN-RY3T-N Manual E5AN-RY3T-N INSTRUCTION Manual
Product model: E5AN-RY3T-N
Name: digital controller
Brand: OMRON
Sort: INSTRUCTION Manual
File language: English
High performance price ratio standard type proximity sensor.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC three wire / wire type.
Shape: shield, M30.
Detection range: 10mm.
Output configuration: PNP.
Action mode: NO. E32-TC200E type: standard type; standard,
Specialty: M3 screws (small),
Shape / detection distance (mm): 270; 220; 125 (50),
Bending radius (mm): R10 E5AN-RY3T-N INSTRUCTION Manual E5AN-RY3T-N
Standard test object (minimum test object) (mm) 1: 1 (0.0005),
Fiber element for meeting diversified needsSize: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: relay output.
Control mode: standard or heating cooling E5AN-RY3T-N INSTRUCTION Manual.
Auxiliary output points: 2 points.
SSR fault detection function for heater with broken line: detection function for single phase heater.
Event input points: -.
Transfer output: -.
Communication: RS-232C.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance E5AN-RY3T-N INSTRUCTION Manual.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultE3JK-D91J diffuse reflection type,
E3JK communication type: mode; shading ON,
Miniature amplifier built-in type photoelectric switchSize: 48 x 96mm.
Control output 1: relay.
Auxiliary (alarm) output: 4.
Transfer output: -.
Event input: -.
Communication: -.
Break detection: -.
Power supply voltage: AC100 ~ 240V.
E5 - C series of new products program.
Maximum 256 segment of the program capacity,
Support for multiple applications.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
The use of high 25mm (E5AC-T), 18mm (E5AC-T) PV display (white),
Improve visibility.
Not only on the top of the body, but also on the front,
The use of communication adapter cable (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CX-Thermo (sold separately).
High speed sampling to achieve 50ms E5AN-RY3T-N Manual.
With auxiliary output (4 points), event input (maximum 6 points), the transmission output,
Support a variety of applications.
Slender fuselage depth 60mm.
Easy to connect with PLC through no program communicatiion E5AN-RY3T-N Manual.
Combined temperature control device through component communication.
Add position proportional control type, also support control valve control.