E32-T24 type: standard type; standard,
Features: with 1 cylinder side (small),
Shape / detection distance (mm): 160; 130; 75 (30),
Bending radius (mm): R10.
Standard test object (minimum test object) (mm) 1: 1 (0.0005),
Fiber element for meeting diversified needsAppearance: Standard.
Sensing method: Through-beam type (with slot) E5AR-A4W-500 INSTRUCTION Manual.
Cable length: 2 m.
Sensing distance: 5 mm (slot width)
E5AR-A4W-500
configuration Output: Dark-ON.
Indicator mode: No incident light.
Model: PNP output.
Slim, Compact Photomicrosensor.
that is still easy to use.
Compact, thin profile enables dense mounting.
Indicator is visible from both sides.
Wide operating voltage range: 5 to 24 VDC. Size: 96 x 96mm.
Control output 1: double relay (proportional valve) E5AR-A4W-500 INSTRUCTION Manual.
Auxiliary (alarm) output: 4.
Transfer output: -.
Event input: 2.
Communication: RS-485.
Break detection: -.
Power supply voltage: AC100 ~ 240V.
E5 - C series of new products program.
Maximum 256 segment of the program capacity,
Support for multiple applications.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
The use of high 25mm (E5AC-T), 18mm (E5AC-T) PV display (white),
Improve visibility E5AR-A4W-500 INSTRUCTION Manual.
Not only on the top of the body, but also on the front,
The use of communication adapter cable (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CX-Thermo (sold separately).
High speed sampling to achieve 50ms.
With auxiliary output (4 points), event input (maximum 6 points), the transmission output,
Support a variety of applications.
Slender fuselage depth 60mm.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.
Add position proportional control type, also support control valve control. Case color: Black.
Control output: Relay output.
Control mode *1: Standard.
No. of auxiliary outputs: --.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, E5GN-RTC;
Resistance thermometer input, E5GN-RP.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5AR-A4W-500 Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5AR-A4W-500 Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.