E32-TC200A type: standard type; standard,
Specialty: M3 screws (small),
Shape / detection distance (mm): 900; 680; 450 (180),
Bending radius (mm): R25.
Standard test object (minimum test object) (mm) 1: 1 (0.006),
Fiber element for meeting diversified needsAmplifier Unit.
Separate Amplifier Sensor with E5AR-PR4DF INSTRUCTION Manual.
Sensitivity Adjustment.
Compact design with smaller Sensor Head
E5AR-PR4DF
Heat-resistance model available for application between.
-10 and 200°C. Size: 1/16 DIN 48 × 48 × 78 (W × H × D).
Power supply voltage: 100 to 240 VAC.
Input type: Thermocouple or Resistance thermometer.
Alarm output: 2.
option units Mounting: No.
Control output: Relay output.
Previous mode: E5CZ-R2.
This Best-selling General-purpose,
48×48-mm Temperature Controller,
Is Now Even Better E5AR-PR4DF INSTRUCTION Manual.
Controllers now available with analog inputs.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Easy setting with 11-segment displays.
Setting protection indicator informs operator when,
protection is enabled E5AR-PR4DF INSTRUCTION Manual.
Manual output provided.
New protocol called Modbus is installed in the models,
with communications.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33. Size: DIN 1/4, 96 x 96 x 78mm.
Power supply voltage: AC100 ~ 240V.
Alarm points: 3 points.
Control output: current.
Input: thermocouple.
New generation intelligent general temperature controller.
The thickness is only 78 mm.
Various temperature inputs: thermocouple, platinum resistance, non contact temperature sensor signal input.
Automatic adjustment and self adjustment.
Automatic adjustment can be performed even when the self adjustment is being performed. Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: relay output.
Control mode: standard.
Auxiliary output points: -.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,,
Further performance improvement E5AR-PR4DF Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E5AR-PR4DF Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.