OMRON E5CN-HR2HH03-FLK Manual E5CN-HR2HH03-FLK INSTRUCTION Manual
Product model: E5CN-HR2HH03-FLK
Name: temperature controller
Brand: OMRON
Sort: INSTRUCTION Manual
File language: English
Element type: J (IC).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 4.8 dia.
Protective tubing length L: 20 cm.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5CN-HR2HH03-FLK INSTRUCTION Manual.
Ideal for the thermal input devices of Temperature Controllers E5CN-HR2HH03-FLK
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V) E5CN-HR2HH03-FLK INSTRUCTION Manual.
Shell color: black.
Control output 1: current output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of / E5CN-HR2HH03-FLK INSTRUCTION Manual.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. E32-D11R type: standard type; soft (new standard),
Specialty: M6 screw,
Bending radius (mm): R; R1.
Standard test object (minimum test object) (mm) 1: (0.005),
Fiber element for meeting diversified needsAppearance: U-shaped.
Sensing method: Through beam (with slot).
Sensing distance: 5 mm (slot width).
Output configuration: Light-ON Dark-ON (2 outputs).
Connection method (Cable length): Pre-wired model with standard cable (1 m).
Output type: PNP.
Meeting Customer Needs with.
Ultra-compact Sensors that Mount.
with M3 Screwws E5CN-HR2HH03-FLK Manual.
Mount using M3 or M2 screws.
Reliable sensing slot depth of 6.5 mm.
Indication of sensing window for easy confirmation of,
insertion depth.
Bright indicator for confirmation from many directions.
Both light-ON and dark-ON outputs provided E5CN-HR2HH03-FLK Manual.
All models available with either standard cable or,
flexible robot cable.
Load short-circuit protection circuit provided.