LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON E5CN-HTQ2H03-FLK Manual E5CN-HTQ2H03-FLK INSTRUCTION Manual
Product model: E5CN-HTQ2H03-FLK
Name: digital controller
Brand: OMRON
Sort: INSTRUCTION Manual
File language: English
Appearance: Shielded, M12.
Sensing distance: 4 mm.
Output: PNP.
Model: Operation mode NO.
Aluminum and Iron Both.
Detectable from Long Distances. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1 dia.
Protective tubing length L: 20cm.
Lead wire type: Heat resistive.
Lead wire length M : 1m E5CN-HTQ2H03-FLK INSTRUCTION Manual.
A Wide Variety of High-precision.
Temperature Sensors E5CN-HTQ2H03-FLK
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5CN-HTQ2H03-FLK INSTRUCTION Manual. Size: 48 x 24mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 1 points.
Power supply voltage: AC/DC24V.
Terminal type: PUSH-IN fastening terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance E5CN-HTQ2H03-FLK INSTRUCTION Manual.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set.
It can be eeasily set by CS-Thermo (sold separately) E5CN-HTQ2H03-FLK Manual. Free change detection direction.
Detection direction can be according to the front, side (up and down, around 90 units) change.
Can be similar to the feeling of a limit switch insstallation E5CN-HTQ2H03-FLK Manual.
Type: detection of variable terminal plate / DC type.
Shape: non shield.
Detection range: 30mm.
Output form: NO PNP + NC (dual output).
Related products