Fitting materials: Stainless steel (SUS304).
Count: 1 .
Accessories: Description, Nut plate;
Material, Stainless steel (SUS304);
Count, 1.
Applicable sensor (mounting pitch on sensor side): E3T-S (9/15).
Page: Dimensions, 12. Sensing method: Diffuse-reflective.
Connection method: Pre-wired M8 connector E5CN-R1TDU USER'S MANUAL.
Sensing distance: 5 to 100 mm (wide view).
Model: NPN output
E5CN-R1TDU
The Standard for Photoelectric Sensors,
with a Secure Track Record of One,
Million Sold Yearly.
Long sensing distance of 30 m for Through-beam Models, 4 m for,
Retro-reflective Models, and 1 m for Diffuse-reflective Models.
Mechanical axis and optical axis offset of less than ±2.5° simplifies,
optical axis adjustment E5CN-R1TDU USER'S MANUAL.
High stability with unique algorithm that prevents interference of,
external light. E32-T11R type: special beam type; long range / high function,
Specialty: M4 screw side flexible fiber,
Shape / detection distance (mm): 520; 400; 250 (100),
Bending radius (mm): R; R1.
Standard test object (minimum test object) (mm) 1: 3 (0.1),
Fiber element for meeting diversified needsSize: M8(Stainless steel)(See note 2 E5CN-R1TDU USER'S MANUAL. ); Single; Unshielded.
Sensing distance: 2 mm.
Connecting method (See note 1.): M8 Connector (3-pin).
Body length: Short.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications. Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of thhe Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5CN-R1TDU MANUAL.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5CN-R1TDU MANUAL.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.