Appearance: M8.
Sensing distance: 2 mm.
Connection method: M8 Connector Models.
Cable specifications: --.
Operation mode : NC .
Pin arrangement: 1: +V, 3: 0 V, 2: Control output.
Applicable connector code: I.
Model: NPN output.
Your Search for Proximity Sensors.
Starts with the World-leading E5CS-Q1KJX-F INSTRUCTION Manual.
Performance and Quality of the E2E.
Standard Sensors for detecting ferrous metals
E5CS-Q1KJX-F
Wide array of variations. Ideal for a variety of applications.
Models with different frequencies are also available to prevent,
mutual interference.
Superior environment resistance with standard cable made of oil,
resistant PVC and sensing surface made of material that resists,
cutting oil.
Useful to help prevent disconnection E5CS-Q1KJX-F INSTRUCTION Manual.
Cable protector provided as a standard feature. Size: 96 × 96 mm.
Control type: 4-loop control .
Control mode: 4-loop standard control, 2-loop heating and cooling control.
Outputs(control/transfer): 4 points: Pulse voltage (2 points) and,
Pulse voltage/current (2 points).
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, 4; Serial communications, RS-485 E5CS-Q1KJX-F INSTRUCTION Manual.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity.
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller.
When using models with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4.0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation).
DeviceNet Communications.
Data setting and monitoring can be performed without special programming. Size: 48 x 96mm.
Control output 1: linear current output.
Control output 2: voltage output (SSR driver).
Auxiliary output: 2 independent points.
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 1 points.
Communication: RS-485.
Event input: 6 points.
Remote SP input: there.
Transfer output: have.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remmote SP input, suitable for a wide range of applications E5CS-Q1KJX-F Manual.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperrature controller is connected to each other by using the component communication E5CS-Q1KJX-F Manual.
A new type of proportional control allows you to control the valve.