Size: 48 x 96mm.
Control output 1: linear current output.
Control output 2:--.
Auxiliary output: 2 independent points.
Power supply voltage: AC100 ~ 240V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: -.
Communication: - E5EC-RR2DSM-800 INSTRUCTION Manual.
Event input: 6 points.
Remote SP input: there
E5EC-RR2DSM-800
Transfer output: have.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply E5EC-RR2DSM-800 INSTRUCTION Manual.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications E5EC-RR2DSM-800 INSTRUCTION Manual.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. Size: 96 × 96 mm.
Control type: Position-proportional control(1 loop).
Control mode: Single-loop position-proportional control(See note.).
Outputs(control/transfer): Relay output(1 open, 1 close) and,
1 current (transfer) output.
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, 4; Serial communications, RS-485.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity.
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller.
When using modelss with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4 E5EC-RR2DSM-800 Manual. 0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation) E5EC-RR2DSM-800 Manual.
DeviceNet Communications.
Data setting and monitoring can be performed without special programming.