Name: Temperature Controller (See note 1.).
Power supply: 24 VDC.
No. of control points: 2.
Control output: Transistor output.
Auxiliary output: Transistor output: 2 pts (sinking).
Functions: Heater burnout alarm (See note 3.), Heating or heat/cool,
control is selectable (See note 4.)Event input: 1 point per Unit E5EN-C3BBL-N INSTRUCTION Manual.
Communications functions: RS-485.
Input type (See note 5
E5EN-C3BBL-N): Thermocouple.
New DIN Track Mounting Temperature.
Controller.
Two channels of temperature control available despite width of,
only 22.5 mm.
The Temperature Controller itself can be replaced without,
changing terminal wiring.
Use in combination with a compact Setting Display Unit to,
reduce communications programming requirements E5EN-C3BBL-N INSTRUCTION Manual.
Front-panel LED indicators for easy operation monitoring.
Power supply and communications wiring not required between,
Units when mounted side-by-side.
CompoWay/F communications protocol supported.
UL, CSA, and CE Marking compliance. Detection methods: the firing pattern.
Detection range: 1m.
Purpose: small,
Small thin space probe;
Interference prevention function with close installationPower supply voltage: DC E5EN-C3BBL-N INSTRUCTION Manual.
Sensing method: Retro-reflective without MSR function.
Sensing distance: 11 m[100 mm](When using E39-R2).
Output configu ration: PNP.
Long-distance Photoelectric Sensor.
That Supports AC/DC Power Supplies.
Long sensing distance that is approximately 8,
times that of our conventional model (for the,
Through-beam and Diffuse-reflective models).
(Through-beam: 40 m, Retro-reflective: 7 m, and,
Diffuse-reflective: 2.5 m.) .
Improved visibility:
A red LED that makes the spot visible.
Large indicators that can be seen even from a,
distance.
Improved operability.
(Enlarged sensitivity adjuster and operation selector)
Freely selectable power supply input (24 to 240 VDC, 24 to 240 VAC).
(Additional types added to the DC type lineup.)
Models with infrared LEDs are also available. Element type: K (CA).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 6.4 dia.
Protective tubing length L: 20 cm.
A Wide Variety of High-precision.
Temperaturre Sensors E5EN-C3BBL-N Manual.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5EN-C3BBL-N Manual.