Sensing method: Through beam (Emitter + Receiver).
Connection method: Pre-wired (2 m).
Sensing distance: 0.8 m (apertures built in).
Model: NPN output .
Stainless Steel Housing Ideal for Food Industry PAT Pending.
Strong resistance against detergents, disinfectants, and jet liquid flow.
Product lineup includes BGS Reflective Models and Through-beam,
Models with built-in slits E5EN-R3H03T-FLK INSTRUCTION Manual
E5EN-R3H03T-FLK
Certified by Ecolab Europe. E3F3-D67 detection method: diffuse reflection type,
Lead extraction: CN M12,
Type: Plastic appearance; NPN output,
Threaded cylindrical photoelectric sensor, built-in amplifier,
Photoelectric sensor with proximity sensor appearance
High anti interference with optoelectronic -IC technologyNew DIN Track Mounting Temperature E5EN-R3H03T-FLK INSTRUCTION Manual.
Controller.
Two channels of temperature control available despite width of,
only 22.5 mm.
The Temperature Controller itself can be replaced without,
changing terminal wiring.
Use in combination with a compact Setting Display Unit to,
reduce communications programming requirements.
Front-panel LED indicators for easy operation monitoring.
Power supply and communications wiring not required between,
Units when mounted side-by-side E5EN-R3H03T-FLK INSTRUCTION Manual.
CompoWay/F communications protocol supported.
UL, CSA, and CE Marking compliance. Protective tubing length: 150mm.
Lead wire length: 1m.
Element type: K (CA).
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent:
Detection for single-phase heaters.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temmperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5EN-R3H03T-FLK Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5EN-R3H03T-FLK Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.