Control output: voltage output (SSR driver).
Auxiliary output: 2 points.
Heating wire breakage, SSR fault detection function: single phase heater detection function.
Event input: -.
Communication: RS-485.
Terminal shape: main unit (no terminal unit).
Power supply voltage: AC/DC24V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type E6B2-CWZ3E-10 INSTRUCTION sheet
E6B2-CWZ3E-10
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating E6B2-CWZ3E-10 INSTRUCTION sheet.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately).
With auxiliary output (maximum 2 points), event input (maximum 1 points), the basic function is complete.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8 E6B2-CWZ3E-10 INSTRUCTION sheet. 5mm). Size: Shielded, M30.
Sensing distance: 10 mm.
Output: Polarity Pin allocations: 1-4.
Operation mode: NO.
Highly Durable Proximity Sensor for.
Tough Environments.
Completely stainless-steel housing.
Aluminum chip immunity.
Embedding installation to metal (steel) fittings.
Chemical resistance certified by Ecolab Europe.
Lineup includes pre-wire models and DC 3-wire NPN output,
models with fluororesin coating. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / mannual, RUN/STOP, alarm), interactive display PV/SV E6B2-CWZ3E-10 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E6B2-CWZ3E-10 Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.