OMRON E8Y-A5Y-R Manual E8Y-A5Y-R INSTRUCTION sheet
Product model: E8Y-A5Y-R
Name: pressure sensor
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Size: 96 x 96mm.
Control output 1: voltage output (SSR driver).
Control output 2:--.
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general).
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type.
Input category: full range multi input E8Y-A5Y-R INSTRUCTION sheet.
Heating wire break, SSR fault detection function: 1 points.
Communication: RS-485 E8Y-A5Y-R
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports E8Y-A5Y-R INSTRUCTION sheet.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications E8Y-A5Y-R INSTRUCTION sheet.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Fuurther performance improvement E8Y-A5Y-R Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee display PV/SV E8Y-A5Y-R Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Related products
OMRON
Differential Pressure Sensor
E8Y-A5Y
OMRON Differential Pressure Sensor E8Y-A5Y
Pressure range: 0 to 5.00 kPa. Digital
OMRON
Differential Pressure Sensor
E8Y-A2C
OMRON Differential Pressure Sensor E8Y-A2C
Pressure range: 0 to 2.00 kPa. Digital
OMRON
Differential Pressure Sensor
E8Y-AR5C
OMRON Differential Pressure Sensor E8Y-AR5C
Pressure range: 0 to 500 Pa. Digital ou
OMRON
Differential Pressure Sensor
E8Y-AR2C
OMRON Differential Pressure Sensor E8Y-AR2C
Pressure range: 0 to 200 Pa. Digital ou