OMRON EJ1G-HFUA-NFLK Manual EJ1G-HFUA-NFLK INSTRUCTION sheet
Product model: EJ1G-HFUA-NFLK
Name: temperature controller
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use EJ1G-HFUA-NFLK INSTRUCTION sheet.
Event input points: - EJ1G-HFUA-NFLK
Transfer output: output (using control output).
Communication: RS-232C.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance EJ1G-HFUA-NFLK INSTRUCTION sheet.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc EJ1G-HFUA-NFLK INSTRUCTION sheet. , can be a key operation. Size: DIN 1/8, 48 x 96 x 60mm.
Power supply voltage: AC100 ~ 240V.
Input type: Platinum resistance.
Alarm points: 1 points.
Control output: voltage output (for driving SSR).
Simple new temperature controller, easy to achieve temperature control.
Good visibility (character height E5CSL:21.7mm, E5CWL:16.2mm (PV), E5EWL:20mm (PV)).
From the front panel depth: 60mm.
Parameter is less, set simple.
Sampling time was reduced to 250ms. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 3.2 dia.
Protective tubing length L: 35cm.
Lead wire type: Standard.
Lead wire length M : 2m.
A Wide Variety of High-precision.
Temperature Sensors EJ1G-HFUA-NFLK Manual.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal EJ1G-HFUA-NFLK Manual.