External power supply: 12 VDC.
Output type: Contact and NPN transistor output.
Supply voltage: 100 to 240 VAC.
2-stage.
DIN 72 × 72 mm Multifunction Counter with a,
Bright, Easy-to-view, Negative Transmissive LCD.
Highly visible display with backlit transmissive LCD.
Selectable display color (red/green) enables checking output status at a distance H5CN-YCN INSTRUCTION MANUAL.
Easy operation with a key for each digit
H5CN-YCN
Perform all basic settings with a DIP switch.
Provides a total and preset counter, batch counter, dual counter,
and tachometer (See note.).
Wide range of inputs accepted for NPN/PNP inputs (multi-inputs) and,
2-wire DC sensors.
Complies with UL, CSA, and CE marking.
Degree of protection: IP54 equivalent (front section only) H5CN-YCN INSTRUCTION MANUAL. Operating method: Incrementing, decrementing, and reversible,
(UP/DOWN A to F) (selectable with rotary DIP switch).
Mounting method: Flush mounting.
Operation modes: N, F, C, R, K, P, Q (selectable with rotary DIP switch).
Input signal method (Count and reset inputs): Contact and transistor input, voltage (H and L).
Control output: 1-stage counters: Contact (SPDT) and transistor,
output (H and L output switchable);
2-stage counters: Contact (SPST-NO) and transistor output,
(H and L output switchable) H5CN-YCN INSTRUCTION MANUAL.
Set value read: Continuous mode, Reset mode (selectable).
Memory backup: Yes/No (Selectable using DIP switch).
Display: Yes (8-mm high 7-segment LED, Up indicator).
Models: 8 digits; 1 stage.
A DIN 72 x 72 mm Best-selling Counter.
Easy setting with thumbwheel switches.
A draw-out construction enables maintenance without rewiring.
Models with 2-, 4-, 6-, or 8-digit displays are also available.
Total Counter models are also Available.
Complies with UL and CSA Marking. Control cycle: a week.
Output number: 2 channel.
Installation method: embedded installation.
Power supply voltage: DC24V.
Japanese label model.
The new standard for use of more convenient timing switches.
On the basis of a week of 2 channel type, the output of 4 channel type / year type also joined the series.
Use the independent key to improve the working performance significantly.
Holiday, holiday and other output OFF have a simple holiday set function H5CN-YCN Manual.
Power OFF can also be set.
Test mode that can be easily recognized by the program.
In accordance with UL/CSA, electrical safety standard certification, EMC standards.
Industry first
Can reduce the set vvalue, achieve fast setting!
The built-in temperature compensation circuit, even in a larger temperature range,
Can also achieve high timing accuracy H5CN-YCN Manual.