Power supply voltage: 24V DC±10%, Ripple (p-p): 10%.
Current consumption: 0.9A max.
Discharge voltage: ±7.5kV.
Discharge method: Variable DC.
Ionization time: 1.5 s.
Ion balance: ±10V max.
Amount of ozone generated: 0.01 ppm,
(Measured at a distance of 50 mm from air outlet).
Indicators: Power (Green), Fan running (Green), Cleaning (Yellow), Alarm (Red) ZJ-BAS074 PDF datasheet.
Main functions: Ion balance adjustment (Automatic and manual)
ZJ-BAS074
External output (for both cleaning and alarm outputs): Photo MOS relay output,
(NPN or PNP)Applied voltage: 30VDC max., load current: 100mA max.
Residual voltage: 1V max.
Discharge stop input: No-voltage contact input, ON: 0V short circuit,
OFF: Open (leakage current: 0 ZJ-BAS074 PDF datasheet. 1mA max.).
Ambient temperature range: 0 to 50˚C (No icing or dewing).
Ambient humidity range: 35% to 65% (No icing or dewing).
Weight (Packaged): Approx. 0.6 kg (Approx. 1.2 kg).
Material: Body:Aluminum, ABS Electrode needle: Tungsten.
Accessories: Instruction sheet, I/O connector, L-mounting bracket, Streamer.
This ionizer series is designed to go anywhere.
All models are easily installed on narrow,
workbenches or in high positions where earlier,
models presented installation issues ZJ-BAS074 PDF datasheet. Actuator: Panel mount roller plunger.
Approved Standards: UL CSA EN.
Small, High-precision Enclosed Switch.
Small, High-precision Enclosed Switches with Built-in Basic,
Switches for High Repeatability and Durability of 10 Million,
Operations Minimum.
Same mounting pitch as Z Basic Switch.
Requires less operating force than conventional limit switches.
Lineup includes modes with operation indicators for easy,
maintenance and inspection.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for Information on approved models.). Classification: Standard.
Contact gap: G (0.5 mm).
Actuator: Short hinge lever.
Best-selling Basic Switch Boasting.
High Precision and Wide Variety.
A large switching capacity of 15 A with high repeat accuracy ZJ-BAS074 datasheet PDF catalog.
A wide range of variations in contact form for your selection: basic,
split-contact, maintained-contact, and adjustable contact gap types.
A series off standard models for micro loads is available ZJ-BAS074 datasheet PDF catalog.
A series of molded terminal-type models incorporating safety,
terminal protective cover is available.