Connects CQM1H to G730 SYSMAC BUS remote I/O
modules; max. 64 I/O (32 or 16 inputs or outputs, DIP switch selectable)
Number of I/O points per Master: 128
Communications cycle time: 187.5 kbps
Max. transmission distance: 200 m
One master and two expansions allowed per systemC500-IA I/O Unit AC Input 16 pts C500-IA222(3G2A5-IA222) CJ1W-TC003 PDF datasheet.
AC200-240V 10mA.Product name: N@@-type CPU Units with 30 I/O Points
CJ1W-TC003
Specifications: Power Supply, 100 to 240 VAC; Inputs, 8; Outputs, 6;
Output type: Relay.
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.17A; 24 V,0.07A.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient CJ1W-TC003 PDF datasheet.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Product name: E@@S type CPU Units with 10 I/O Points.
Specifications: Power Supply, 24 VDC; Inputs, 6; Outputs, 4;
Output type: Transistor (sinking) CJ1W-TC003 PDF datasheet.
Program capacity: 2K steps.
memory Data capacity: 2K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.11A; 24 V,--.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. One of the following connection cables is required for ladder programming.C500-ID I/O Unit DC Input 64 pts C500-ID114(3G2A5-ID114).
DC12V 7mA.Communications protocol: Dedicated CompoBus/S protoco.
Code: Manchester code.Name: Clamp Terminal Blocks.
Specifications: Inputs; 8 inputs ; NPN; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced. CJ1W-TC003 datasheet PDF catalog.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CJ1W-TC003 datasheet PDF catalog.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.