Unit type: CJ1 Basic I/O Units.
Product name: Triac Output Unit.
Specifications: Output type , --;
I/O points, 8 inputs;
Maximum switching capacity, 250VAC, 0.6A;
Commons, 8 points, 1 common;
External connection, Removable terminal block.
No. of words allocated: 1 word.
Current consumption: 5V, 0 CP1L-L10DR-A PDF datasheet. 22A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications
CP1L-L10DR-A
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput. Name: e-CON Connectors CP1L-L10DR-A PDF datasheet.
Specifications: Outputs; 32 outputs; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site CP1L-L10DR-A PDF datasheet.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Unit type: CS-series Special I/O Units.
Product name: Analog Input Units.
Specifications: I/O points, 4 inputs;
Signal range selection,
Set separately for each input;
Signal range, 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 V to 10 V, 4 to 20 mA;
Resolution, 1/8,000 (Settable to 1/4,000);
Conversion speed, 250 s/point max.
(Settable to 1 ms/point).
Externa connection, Removable terminal block.
Current consumption: 5V, 0.12A; 26V, 0.09A.
Standards: UC1, N, CE.
For Various Analog I/Os.
Analog Input Units for converting,
analog input signals into binary data.
Analog Output Units for converting ,
binary data into analog output signals. Name: e-CON Connectors.
Specifications: Inputs; 32 inputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system CP1L-L10DR-A datasheet PDF catalog.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CP1L-L10DR-A datasheet PDF catalog.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.