Description: Operates as a DeviceNet slave.UM: 31.2K words.
DM: 6K words.
EM: 6Kx3 banks(18K) words.
Instruction processing time (basic instructions): 0.1 µ.s min.
No. of I/O points: 880 points.
Max. no.of con-necting Expansion I/O Racks: 2 Racks.
Max. no. of connecting High-density I/O Units(i CRT1-ROF08 PDF datasheet. e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10
CRT1-ROF08
RS-232C: NO.Output method: Transistor sinking.
Inputs: 12.
Outputs: 8.C500-CP Special I/O Unit Cam Positioner Unit C500-CP131.C200H A Backplane I/O Mounting Bracket For 8 Slots C200H-ATTA3.Name: Temperature Input Units.
Specifications: Thermocouple Input; 4 inputs;
Switchable between.
(R, S, K, J, T, E, B, N, L, U, W, PL2)
Standards: CE, UC, UC1, N CRT1-ROF08 PDF datasheet.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site CRT1-ROF08 PDF datasheet.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Product name: N@@-type CPU Units with 30 I/O Points.
Specifications: Power Supply, 24 VDC; Inputs, 8; Outputs, 6;
Output type: Transistor (sourcing).
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.22A; 24 V,0.02A.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Unit classification: CJ1 Special I/O Units.
Product name: Highspeed Counter Unit.
Specifications; Countable channels: 2 ,
Encoder A and B inputs, pulse input Z signals;
Open collector Input voltage: 5VDC, 12V, or 24V,
(5V and 12V are each for one axis only.) ,
Max. counting rate, 50kHz.
No. of unit numbers allocated: 4.
Current consumption: 5V, 0.28A; 24V, --.
Standards: UC1, N, L, CE.
High-Speed, Flexible Control With A,
Wide Array off Features CRT1-ROF08 datasheet PDF catalog.
Equipped with 2 Counters and counts ,
over a maximum binary range of 32-bits.
Accepting input pulse frequencies of up,
to 500 kHz allows precise control of fast motions.
The Unit is equipped with 2 DDigital Inputs,
2 Digital Outputs and 30 Soft Outputs CRT1-ROF08 datasheet PDF catalog.
A maximum response time of 0.5 ms guarantees,
high-speed closed loop control of applications.