C500-NC Special I/O Unit C/CV Servo Module Single Axis Stepper C500-NC111-V1.Name: Analog I/O Slave Units,
(Numerical indicator type)
e-CON Connector Type.
Specifications: Analog outputs; 2 outputs.
Standards: CE.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet CS1D-CPU67H PDF datasheet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system
CS1D-CPU67H
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error CS1D-CPU67H PDF datasheet. C500-ID I/O Unit DC Input 32 pts C500-ID218(3G2A5-ID218).
DC12-24V 10mA.C500-AD Special I/O Unit Analog Input C500-AD101.
Input: 8 pts.
Specification: 0~+10V、4~20mA.I/O Control UnitC500-OD I/O Unit Transistor Output 16 pts C500-OD411(3G2A5-OD411).
DC12~48V 1A.Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 4 inputs CS1D-CPU67H PDF datasheet.
Signal range: 4 to 20 mA, 0 to 20 mA,
0 to 10 V, ±10 V, 0 to 5 V, ±5 V,
1 to 5 V, 0 to 1.25 V, ±1.25 V.
Conversion speed (resolution):
20 ms/4 inputs, 10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.12A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
wwith previous systems CS1D-CPU67H datasheet PDF catalog.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1D-CPU67H datasheet PDF catalog.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.