Protector for Simple Expansion I/O Rack connector CV500-COV04Name: Temperature Control Module.
Model: C200H-TC102.
Sensor: Platinum resistance thermometer: JPt100 Pt100.
Control output: Voltage output.CV500-HD SYSMAC BUS PC Unit Hard Disk Unit 80MB hard disk CV500-HDD11.
CV500-HDD11: 80MB x 2.C500-AS Special I/O Unit ASCII BASIC UNIT C500-ASC01 CS1W-LCB01 PDF datasheet. Name: Position Control Module
CS1W-LCB01
Model: C200H-NC211.
Control method: Open-loop, automatic trapezoid acceleration/deceleration.
Control output sig-nals: Pulse-train outputs.
Controlled axes: 2.Model: CPM2C-32EDT1C. Units with 32 I/O points
2 Fujitsu connectors.
Inputs: 16 inputs.
Outputs: 16 outputs.
Input type: 24 VDC.
Output type: sourcing transistor CS1W-LCB01 PDF datasheet. Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit.
I/O points: 4 outputs;
Signal range selection:
Set separately for each output.
Signal range, Resolution: 1 to 5 V,
0 to 5 V, 0 to 10 V, -10 to 10 V,
4 to 20 mA; 1/4,00.
Conversion period: 1 ms/point.
Accuracy at ambient temperature of 25°C:
Voltage: ±0.3% of F.S. Current: ±0.5% of F.S.
External connection: Removable terminal block CS1W-LCB01 PDF datasheet.
External power supply: 24 VDC +10% -15%, 200mA max.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 24V, 0.2*3.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Analog Input Units for converting analog input,
signals into binary data.
Analog Output Units for converting binary ,
data into analog output signals.
Model: CPM2A-20CDR-D. Power supply: DC power supply.
Output type: Relay.
Inputs points: 12 points.
Outputs points: 8 points.Supply voltage: 100 to 120 or 200 to 240 VAC (automatic voltage setting), 50/60 Hz
Operating voltage range: 85 to 132 or 170 to 264 VAC
Power consumption: 150 VA max.
Output capacity: 8 A, 5 VDCName: MIL Connectors.
Specifications: Outputs; 16 outputs ; NPN; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced. CS1W-LCB01 datasheet PDF catalog.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CS1W-LCB01 datasheet PDF catalog.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.