Release key type: Special release key.
Indicator: Orange.
Lock and release types: Solenoid lock Mechanical release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 3NC+2NC/1NO.
Conduit opening: M20.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns D4N-2B2HR PDF datasheet.
Standard gold-clad contacts enable use with ordinary loads,
and microloads
D4N-2B2HR
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection. Lock method: Solenoid lock D4N-2B2HR PDF datasheet.
Conduit size: G1/2.
Voltage for solenoid: 24 VDC.
With LED indicator 1NC/1NO+ 1NC (Slow-action).
Release Protective Cover Locks Using.
Controller Signals or Pushbutton.
Switches after the Cutting Tool Stops.
Moving Due to Inertia.
A mechanical lock is applied automatically when the Operation.
Key is inserted. A high level of safety is achieved using a,
mechanism where the lock is only released when voltage is,
applied to the solenoid D4N-2B2HR PDF datasheet.
Conforms to EN (TÜV) standards corresponding to the CE marking.
Certified by UL, CSA and CCC standards.
The Switch contact is opened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened.
Direct opening mechanism that is EN-certified is indicated by,
on the Switch.
Auxiliary release key ensures easy maintenance and unlocks the,
door in the case of a power failure.
Tough aluminum die-cast body incorporating a switch box with,
degree of pprotection satisfying IP67, UL, and CSA TYPE6P, 13 D4N-2B2HR datasheet PDF catalog.
Equipped with a horizontal and vertical conduit opening.
Models incorporating easy-to-see indicators for monitoring and,
those using an adjustable Operation Key ffor a swinging door are available D4N-2B2HR datasheet PDF catalog.
The mounting direction of the head can be changed,
to allow the Operation Key to be inserted from four directions.