LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Catalog Download
OMRON E2A-M18LN16-M1-B2 datasheet PDF catalog E2A-M18LN16-M1-B2 PDF datasheet
Product model: E2A-M18LN16-M1-B2
Name: Cylindrical Proximity Sensor
Brand: OMRON
Sort: PDF datasheet
File language: English
Appearance: Shielded, M18.
Sensing distance: 8 mm.
Output: PNP.
Model: Operation mode NC.
Aluminum and Iron Both.
Detectable from Long Distances. Control output: voltage output (SSR driver).
Auxiliary output: 2 points.
Heating wire breakage, SSR fault detection function: single phase heater detection function E2A-M18LN16-M1-B2 PDF datasheet.
Event input: -.
Communication: RS-485.
Terminal shape: screw terminal table type (main unit + terminal unit) E2A-M18LN16-M1-B2
Power supply voltage: AC/DC24V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body E2A-M18LN16-M1-B2 PDF datasheet.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately) E2A-M18LN16-M1-B2 PDF datasheet.
With auxiliary output (maximum 2 points), event input (maximum 1 points), the basic function is complete.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm). Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: silver.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 4.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermmostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E2A-M18LN16-M1-B2 datasheet PDF catalog.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output E2A-M18LN16-M1-B2 datasheet PDF catalog.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.
Related products
OMRON
Cylindrical Proximity Sensor
E2A-M18LS08-M1-C2
OMRON Cylindrical Proximity Sensor E2A-M18LS08-M1-C2
Size: M18, Shielded. Sensing distance:
OMRON
Cylindrical Proximity Sensor
E2A-M18LN16-WP-C2 2M
OMRON Cylindrical Proximity Sensor E2A-M18LN16-WP-C2 2M
Size: M18, Non-shielded. Sensing distan
OMRON
Cylindrical Proximity Sensor
E2A-M18LN16-WP-B2 2M
OMRON Cylindrical Proximity Sensor E2A-M18LN16-WP-B2 2M
Size: M18, Non-shielded. Sensing distan
OMRON
Cylindrical Proximity Sensor
E2A-M18LS08-WP-B2 2M
OMRON Cylindrical Proximity Sensor E2A-M18LS08-WP-B2 2M
Size: M18, Shielded. Sensing distance: